‧AC‧SK1238 (E)

Dia.113x40.5mm / 4.5inch
110~50 CFM
Plastic Impeller
  Rated
Volt
Voltage
Range
Freq Input
Power
Ref.
Speed
Max.Airflow Max.Static Pressure Noise
Level
PQ UL
Model No VAC VAC Hz Watt

RPM

CFM m3/min Inch/H2O mm db(A)    
SK1238AN-11-HHH** (E) 115 100~120 50/60 17/15 2700/3100 93/110 2.6/3.1 0.29/0.32 7.37/8.13 43 2/1 £
SK1238AN-11-HH** (E) 115 100~120 50/60 13/11 2500/2300 83/72 2.4/2 0.22/0.19 5.59/4.83 37 4/3 £
SK1238AN-11-H** (E) 115 100~120 50/60 10/8 1950/1300 68/50 1.9/1.4 0.18/0.14 4.57/3.56 29 6/5 £
SK1238AN-22-HHH** (E) 230 200~240 50/60 17/15 2700/3100 93/110 2.6/3.1 0.29/0.32 7.37/8.13 43 2/1 £
SK1238AN-22-HH** (E) 230 200~240 50/60 13/11 2500/2300 83/72 2.4/2 0.22/0.19 5.59/4.83 37 4/3 £
SK1238AN-22-H** (E) 230 200~240 50/60 10/8 1950/1300 68/50 1.9/1.4 0.18/0.14 4.57/3.56 29 6/5 £
SK1238AN-4-HHH** (E) 24 24~28 50/60 17/15 2700/3100 93/110 2.6/3.1 0.29/0.32 7.37/8.13 43 2/1 £
SK1238AN-38-HHH** (E) 380 380~420 50/60 17/15 2700/3100 93/110 2.6/3.1 0.29/0.32 7.37/8.13 43 2/1 £
SK1238AN-44-HHH** (E) 440 440~480 50/60 17/15 2700/3100 93/110 2.6/3.1 0.29/0.32 7.37/8.13 43 2/1 £
SK1238AN-11/22-HHH** (E)
dual voltage
115
230
100~120
200~240
50/60 17/15 2700/3100 93/110 2.6/3.1 0.29/0.32 7.37/8.13 43 2/1 £
  • The stated airflow, air pressure, noise levels are measured with housing orifice dia.: impeller Φ +1~1.5mm, at distance: approx. height of impeller + motor frame. The optimal operating data can only be depended on the installation conditions.
  • ** = "WB" for wire lead type Ball bearing, or "TB" for terminal type Ball bearing
  • 100, 200, 240V or special voltages 12, 24, 28, 38, 42, 48, 380~440~480... 50/60Hz, & dual voltage version available on request.
  • Dual speed High/Medium 1/2, High/Low 1/3, Medium/Low 2/3, Low/extra Low 3/4 or triple speed 1/2/3 available on request.
  • Sinwan reserves the right to change data and improve electrical or mechanical design without notice, data tolerance +-10%
  •  
      Motor Type: Shaded pole induction, 1-phase
      Burnout Protection: Impedance protected
      IP Protection: IP44
      Frame: Aluminum diecasting , 7 mounting holes dia.2.3mm or tapped M3
      Impeller: Glass fiber reinforced PBT thermoplastic impeller, UL94V-0
      Bearing: Two precision double sealed ball bearings
      Rotation: CCW seen on rotor
      Connection: Wire lead
      Weight: 395g (0.87Lbs)
      Dielectric Strength: Over 1 minute at 1,500 VAC, 0.5mA, 50/60 Hz
      Insulation Resistance: Over 100 MΩ at DC 500V
      Signal Output: -
      Operating Temp: Ambient non-condensing -20~+70C
      Storage Temp: -40C~+100C (at 65%RH)
      Life Expectancy: 55K hours at 45°C, 25K hours at 65°C based on life test Formula L10